100 amp sub panel ground wire size - Main panel is outside. Subpanel will be in the basement. 70 Amp breaker in the main to feed the subpanel. I was thinking THHN but would this mean I need to run the conduit all the way to the subpanel? Would NM-B be ok? Edit: I live in Colorado if that makes any difference and I think the wire size is #6 for THHN and #4 for NM-B.

 
The main panel should be grounded (probably with 2 grounding rods) and the grounded (neutral) and grounding buses should be bonded in the main panel. The subpanel probably isn't far enough away from the main to require its own grounding rod (s), but regardless, it does require a 4 wire feed from the main panel (2 ungrounded …. Oaxaca costco

1 Power Factor is assumed to be 0.90. 2 Temperature Rating assumed to be 75°C. 3 Weights are approximate and do not include insulation weights. 4 Values Per 1000 feet. 5 Maximum length is based on a load that is 80% of the fuse size. Prove Productivity Impacts with Real-Time Condition Tracking. Easily Calculate Lost Hours on Remaining Work.To go from the 200 amp Main Panel to barn would add an extra 100' roughly as its a long ranch house and would have to go around a big concrete patio. Ron, What is the load on the house and what loads are being added to the pole barn. Without that info you are working in the dark.I am running 100 amp line from my service panel to my subpanel through 100' of underground PVC. I have to use copper per local code. I am going to use #3 Cu for my two hot wires. 1) What AWG size does my neutral wire have to be? I found this: Per NEC Sec. 220-22.For a circuit protected by a 100 A breaker, the minimum ground wire size is #8 copper or #6 aluminum. Jason, A separate building always requires a grounding electrode system in addition to the equipment grounding conductor that you mention.Wire size for 100 amp basement sub-panel. Have a 200 amp main in my attached garage. I am adding a 100 amp sub-panel in my basement to run all my basement circuits (2 bedrooms, office, living room, wet bar, bathroom). I have a panel with breaker set in the basement, and already have the 100 amp breaker to go in the main in the garage, but need ...90 Amp Wire Size Calculator. In this calculator, you just insert 90 amp wire length, voltage (12V, 120V, 220V, and so on), and allowable voltage drop (3%, 5%, 10%), and the calculator will automatically determine the copper wire gauge for 90 amp service. ... Example: Let's say we want to run a 90 amp 240V wire to a sub-panel 400 feet away ...The right wire size for an 80 amp breaker is a 2 or 3-gauge wire. It is thick enough to carry the current produced by the 80 amps service. The 4 gauge wire is sometimes also considered the standard size for 80 amps. If you use aluminum wires, the size would be 1 or 2-gauge wire. The wire size can vary based on factors like the wire …Sub panel wire size & Amp rating chart: Amp rating Aluminum wire gauge size (AWG) Copper wire gauge size (AWG) 125-amp: 1/0: 1: 100 amp: 1: 3: 60 amp: 4: 6: 50 amp: 6: 8: 40 amp: 8: 8: 30 amp: 8: 10: 20 amp: 10: 12: Final thoughts. A 125-amp sub panel indicates how many items you may run and how much electricity can be securely provided into ... When choosing the wire for a 100 amp subpanel, you need to make sure that the wire gorge is sufficient for the amperage of the sub panel. Generally, a 100 amp sub panel requires #4 copper wires or #2 aluminum wires. 100 amp sub panel wire size: Generally, the wire that is suitable to run a 100amp subpanel is #4 copper wires or #2 aluminum wires. How did you get #1 wire into a 100 amp breaker? You should run 3- #4 insulated wires for your 2 hots, and neutral. Outside of the conduit, run a #4 solid copper ground wire. In the sub panel, ground and neutral must be separate. There should be no bonding of the ground and neutral in the sub panel. You say: " I looked it up, and it looks OK,"The minimum width is 30 inches or the width of the panel, whichever is greater. The depth, i.e. the distance between the front of the panel and any obstructions, needs to be at least 36 inches. The minimum height is 6-1/2-feet. A good comparison for the clearance space, says Williamson, is the size of a standard refrigerator.100 amp ground wire sizeAutomation community: electrical wire size table Installing 200 amp meter pole for mobile home. what size wire for a 80Panel sub amp subpanel 60 wiring diagram breaker electrical square circuit install wire box main size installation ge switch breakers.For a 100-amp service, the minimum required conduit size is 4 AWG to 1 ¼ inch. Different wire sizes are available depending on the service panel. That's why the safe wire size for a 100-amp service panel is 4 AWG to 1 ¼ inch. It's been accepted globally as AWG standards are used to measure wire. Nusrat Sabrin.How to Install a Sub Panel for an Attached Garage. Planning and Installing a Garage Sub Panel: Do This Before Installing a Garage Electrical Panel, Check the Main Panel, Select the Wire Type and Wiring Method, Check the Wiring Path, Outlets and GFCI Requirements, Electrical Code Compliance. Considerations When Planning An Electrical …-1. I am adding a 100 amp sub panel off the 100 amp main breaker. Don't understand the directions on what wire size to use. I bought the PowerMark Gold 100 …Mobile broadband subscriptions in Sub-Saharan Africa are forecast to grow by 16% a year to 880 million subs by 2023 It is easy to glaze over the impact of the mobile phone in Afric...If this is a new installation, you should have an EGC (ground wire) running back to the main panel, in addition to the ground rod (4 wires total), with the neutral and ground remaining separate back to the main panel. If, however, you have 3-wire service to the garage, neutral and ground *must* be bonded in the subpanel.At the panel on the barn, do I need to "re-ground" the panel if the aluminum wire is connected to the main panel ground bus? I would plan for an 160amp draw (80% load of 200amp) at the entrance panel on the barn, is this the correct assumption? ... What size wire for a 100 amp sub panel in a barn? 0. What wire to use from main panel to subpanel. 0.I need to run power from my house out to my 35X70 workshop out back. What I have; a dedicated panel with 150 amp breaker on the side of my house that is currently only powering my well. My workshop is 275 ft. away. I intend on putting a 100 amp sub-panel in the shop. I have most of the 2” conduit ran in a trench from my house to …200 amp service entrance to 200 amp sub panel? Ask Question Asked 6 years, 9 months ago. ... EMT or rigid metal is recommended, but PVC can be used if you're willing to toss the ground wire in there. In the indoor panel, the hot conductors land on the main lugs or main breaker there, while the neutral lands on the neutral lug and the ground (if ...In case of 125-amp sub panels, you need to have a minimum 2/0 AWG aluminum wire to capacitate the electrical supply size but it is safer to use a wire with higher thickness – which would make it less prone to heating up over time. Higher electrical flow causes the wire to heat up, therefore you need to use a thicker wire made of heat-tolerant ...The type of colored wire you use should be decided by the amperage of your subpanel. For example, a 50 amp panel uses #8 THHN wire. Get some snacks and drinks. It could easily cost you 2 hours to wire the subpanel to your detached garage — you want to stay energized and hydrated especially if you are working during the summer time.Updated on February 15, 2024. According to the NEC, the wire size for 200 amp service is a 3/0 AWG copper wire or 4/0 AWG aluminum wire. You should increase wire size by 20% for every extra 100 feet run to account for voltage drop. For a 200-amp cable size spanning over 200 feet, choose a 500 kcmil copper wire or a 1000 kcmil aluminum wire.In this video, I show you how to install and wire an electrical sub panel. You see the complete process, from start to finish. 00:00 Intro03:02 Purchasing ...Options include THHN, XHHW, UF-B, USE, and SER. Typical sizes of wires for 100 Amp Service are 4 AWG or 2 AWG for copper wiring and 2 AWG, 1 AWG, or 1/0 AWG for aluminum or copper-clad wiring. These sizes are also used for direct burial. When choosing 100 amp service wire size, remember that a 100 amp circuit at 240V can proceed up to 24,000W ...For that service would use URD Aluminum 4 conductor cable (need 2 hot, neutral and should have separate ground to shop, grounds isolated from neutrals in shop panel. for 300 feet for 100 amp rated service I would use Aluminum direct burial 1/0-1/0-1/0-1/0, the forth can be as low as #4 for the ground (but also in conduit, even if in conduit ...The calculator is designed to accept the total line voltage and current of the combined three cables. The equation for the area of a single wire is modified to: A = \frac {\sqrt 3 I \varrho L} {V} A = V 3I ϱL. The factor of \sqrt 3 3 is needed to convert between the system's phase current and line current.Electrical - AC & DC - Wire Size for 150 Amp Subpanel - We're wiring a new house - 200 amp main panel and 150 amp subpanel. All of our high-draw equipment is on the opposite side of the house from the main panel, so we'll be running very little directly from the main panel. Table 310.16 says 1 AWG THHN can handle60 ampere double pole breaker in the main panel. 6 AWG copper wire (x4) for a run less than 75ft., 4 AWG copper wire (x4) for runs less than 150ft. 60 ampere panel with 60 ampere main breaker. Unless you're running a whole bunch of stuff at once, a 60 amp panel should serve you well.Our most popular. Click here for pricing on #3 gauge THHN wire. 2.) #2 THHN/THWN-2 Wire for 100 amp sub-panel. Single Conductor #2 gauge THHN Copper Wire. Needs to be buried in a conduit. Click here for pricing on #2 gauge THHN wire. 3.) #2/3C with ground Tray Cable (THHN-PVC) for 100 Amp Sub-Panel. Multi-Conductor #3 gauge THHN Copper Wire.2. YES you can use #4 Al as your ground. Your 1AWG Al is good for a 100 AMP feeder (actually 110). From NEC 250.122 this requires an #8 CU or #6 Al ground wire as a minimum (or 6CU and 4 Al if you are really running a 110Amp Feeder). As a reminder, your feeder will be 4 wires, the two hots and the neutral will be #1AL (unless you've de-rated ...The further away the panel is, the larger the wire size needs to be. This is because voltage drop can occur over long distances, and a larger wire size will help to minimize this drop. ... What is the recommended ground wire size for a 100-amp service? For a 100-amp service, the recommended ground wire size is #8 copper or #6 aluminum. ...180. 180. From the above table, if we apply the 83% rule, then the minimum required conductor size must be calculated for 83% of 100 Amps i.e., 83 Amps. So, the 100 Amp Wire Size with an 83% rule is AWG 4 for Copper Conductors and AWG 2 for both Aluminum and Copper-Clad Aluminum Conductors.Running 2 - 100 amp sub-panels you should run #3 THHN wire to each panel with a 100 amp breaker to feed each one. The NEC recommends 3% voltage drop for either the feeder or the branch circuit and 5% total for both. This is only a recommendation and never appears in the text of the code so it not enforceable. However, it is a very good idea.NEC Annex C, Table C10 says 3 XHHW's will fit in 2". I know wires will fit in smaller but going with 60% fill requirements and pulling ease. Even 2" will suffice. But go 2 1/2", it's easier to pull the wire. 3" is clearly not needed.#4 copper is good for 85 amps which means that you can go up to the next standard size which is 90 amps. ... My last project had over 720 apartments and each unit had it's own 100 amp panel. All of the feeders that were less than 100' (600+) were #3. ... You can pay 80c for a cat6 jack, or 7$ a piece. Wire is about a 2 fold difference. J ...Our Omnicalculator 100 amps wire size tool indicates that for 100 feet, 110 volts (three-phase), you should consider a 2 AWG cable. How many watts is 100 amps? 8,800 watts to 18,400 watts in a single-phase system (110 volts to 230 volts) with a power factor of 0.8.The breaker size for the 125 AMP panels is defined based on the panel's highest current ability. The panel breaker size is not larger than its highest rating. For 120 AMP panels, there is the use of a 60 amp DOUBLE pole breaker. 14/3 copper feeder needs a 15A breaker. 12/3 copper requires a 20A breaker.The minimum ground wire size for 100 amp service is 8 AWG copper or 6 AWG aluminum wire. It can change based on several factors. ... What is the wire size for a 100-amp sub panel? The grounding wire for the leading service and breaker box will also work for the sub-panel. For a 100 amp sub panel, you can use an 8 AWG or 6 AWG wire.The National Electric Code (NEC) requires a #4 American Wire Gauge (AWG) copper wire for sub-panels. If using an aluminum or copper-clad aluminum wire, a #2 AWG wire can be used. The minimum conduit size is 1.25 inches and a schedule 40 or 80 PVC electrical conduit is specified for lines run underground. However, wiring …These sub-panels are connected to the ground wire. The primary role of the ground rod is visible when lightning strikes. ... With the 80% NEC (National Electric Rule), the best size for a 100amp sub-panel is 1 AWG (American wire gauge). 1 AWG has 130amp ampacity but can conduct at most 104 amps. Most houses use copper wire for …Here is the equation for voltage drop: Voltage Drop = 2 × L × K × 125 Amp / Circular Mils. At 120V, the 3% voltage drop is 3.6V (120V×0.03 = 3.6V). The L in the equation stands for wire length, and K is the specific resistivity of the wire material (12.9 ohms for copper wires and 21.2 ohms for aluminum wires).But if the sub-panel is located in a detached building, let us say the garage, then you also need to "ground the panel" by running a wire from its ground bar to planet Earth (e.g., to a ground rod or two). That wire would be the GEC that Bob mentioned, and it is sized per 250.66.What size wire for 100 amp service 100 feet away? For a 100 amp service 100 feet away, a #2 AWG copper wire might be suitable, but consider voltage drop and local codes. What gauge wire do I need for 100 amp sub panel? For a 100 amp subpanel, you might need a wire gauge like #2 AWG copper or #1/0 AWG aluminum, based on distance and other factors.The new panel will be 125 amp rated, the new conductors will be #3 THHN, with an ampacity rating of 115, which will be protected by a 100 amp 2 pole breaker in the main panel. What size does the grounding conductor leading back to the main panel need to be?I'd like to confirm my understanding of. the distance: #3 AWG will work for my distance (I believe #4 AWG would work for < 100', and #3 would suffice for my distance). the fill %. I've found tables that refer to max wires of equal size, and a few statements of the % conduit fill. One conductor: 53% of the conduit space. Two conductors: 31%.Not if sure if I can get the 100 amp breaker out of sub panel to put in 60 amp. ... The grounded conductor needs to be isolated from the can and an equipment ground included in the feeder. Easy enough on most panels. Are some listed for use as Service Equipment Only? Increase the size of the wire from the 60 to the 100 if the latter's range is ...NEC Annex C, Table C10 says 3 XHHW's will fit in 2". I know wires will fit in smaller but going with 60% fill requirements and pulling ease. Even 2" will suffice. But go 2 1/2", it's easier to pull the wire. 3" is clearly not needed.looking for what size wire do i need to put in a 100 amp sub panel with a 150'run off a 400 amp service. new panel will run 60 amp hot tub and sonme lights and ceiling dfans Stack Exchange Network Stack Exchange network consists of 183 Q&A communities including Stack Overflow , the largest, most trusted online community for developers to learn ...A 100 Amp panel could have a huge load - as much as 80 Amp continuous, or a tiny load - as little as 20A (with occasional higher amounts). ... Wire size for 100 amp subpanel in detached garage 215' away. 1. ... Direct Burial Wire for 200 Amp Sub Panel from 200 Amp Main. 0. Main Panel Electric Question. 2. Grounding Main Sub-panel …A 40 amp breaker needs a minimum of 8 gauge, larger gauge won't hurt. If using 39 amps (actual) at the same time, then you might need to use a 50 amp breaker with 6 gauge wire minimum. If sub panel is in the same building then I think you only need the ground wire back to main. - crip659. Jul 12, 2022 at 23:08.looking for what size wire do i need to put in a 100 amp sub panel with a 150'run off a 400 amp service. new panel will run 60 amp hot tub and sonme lights and ceiling dfans Stack Exchange Network Stack Exchange network consists of 183 Q&A communities including Stack Overflow , the largest, most trusted online community for developers to learn ...If the wire run is over 100 feet in length, then 4-gauge wire may be necessary. Generally, a 100 amp sub panel will require 6-gauge wire, though larger gauge wire can be used depending on the length of the run. The size of the wire required for a 100 amp sub panel depends on the length of the wire run and the type of wire you are using.Jan 20, 2023 · 180. 180. From the above table, if we apply the 83% rule, then the minimum required conductor size must be calculated for 83% of 100 Amps i.e., 83 Amps. So, the 100 Amp Wire Size with an 83% rule is AWG 4 for Copper Conductors and AWG 2 for both Aluminum and Copper-Clad Aluminum Conductors. It's perfectly legal to feed a panel rated for "X" amps with a breaker smaller than "X" (and corresponding smaller wire). The rating is a maximum, not a level you're required to achieve. You may not have load-calculation capacity for an extra 100A, 90A wire can be significantly less expensive than 100A wire, etc. – nobody.Updated on February 15, 2024. According to the NEC, the wire size for 200 amp service is a 3/0 AWG copper wire or 4/0 AWG aluminum wire. You should increase wire size by 20% for every extra 100 feet run to account for voltage drop. For a 200-amp cable size spanning over 200 feet, choose a 500 kcmil copper wire or a 1000 kcmil aluminum wire.A brief visit to the code indicates that there is a bigger problem, in that the ampacity of 8Ga copper is only 55 at 90C (aluminum 45 Amps) so your wire is too small for a 100 amp service. You need a bare minimum (if everything is rated for 90C) of 3Ga copper or 2Ga aluminum, and probably larger after various derating factors are applied, or if 75C is the limit on any connection.NEC § 152.28 UNDERGROUND INSTALLATIONS. (A) National Electric Code (NEC) Table 310-13 identifies acceptable types of underground service entrance cable. Underground feeder and branch circuit cable shall be an approved type UF cable in sizes No. 14 copper, or No. 12 aluminum or copper-clad aluminum through No. 4/0.Boeing notified 16 customers of a potential wiring issue on recently delivered 737 Max jets, the latest problem for the jet. Just months after global aviation regulators lifted the...Your 1AWG Al is good for a 100 AMP feeder (actually 110). From NEC 250.122 this requires an #8 CU or #6 Al ground wire as a minimum (or 6CU and 4 Al if you are really running a 110Amp Feeder). As a reminder, your feeder will be 4 wires, the two … 4 AWG copper ground wire for 200 amp service (at short distances). 0 AWG aluminum ground wire for 200 amp service (at short distances). Now, this is relevant is the hot wire is short. If you need a 200 amp service 50 feet, 100 feet, 150 feet, or 200 feet away (Example: 200 amp sub-panel 100 feet away), you also need to account for voltage drop. A 150-amp main panel is commonly used as the primary electrical service for residential and small commercial buildings. This capacity is generally adequate to meet the power demands of a typical household or small-scale commercial operation. However, determining what size wire for 150 amp service is crucial. While 1/0 AWG is often recommended ...The National Electric Code (NEC) requires a #4 American Wire Gauge (AWG) copper wire for sub-panels. If using an aluminum or copper-clad aluminum wire, a #2 AWG wire can be used. The minimum conduit size is 1.25 inches and a schedule 40 or 80 PVC electrical conduit is specified for lines run underground. However, wiring …In fact, the most appropriate wire size for 100 amp service is the #1 AWG wire with a 130 amp median capacity. To understand why this is, and what wire size you need for 100 …What size wire for 100 amp service 200 feet underground? ... How many ground rods for a 100 amp sub panel? The number of ground rods required for a 100-amp subpanel can vary based on local electrical codes and soil conditions. In some cases, two ground rods may be recommended, spaced a certain distance apart, to ensure a proper ground ...The minimum conductor size allowed is #1 aluminum, which is 83.7 kcmil in cross-section. The minimum ground wire size allowed is #6 aluminum, which is 26.3 kcmil in cross-section. When you enlarge the conductors for any reason, you must also enlarge the ground in proportion. So the ground is 26.3/83.7 = 31.4% of the conductors.It is important to remember that the size of the ground wire should match the size of the other wires that come into the subpanel. ... Yes, you can use #4 wire for a 100 amp sub panel, as long as the distance between the main panel and the sub panel is less than 90 feet. The National Electrical Code (NEC) allows #4 AWG copper conductors for a ...For a 100 amp sub panel located within 100 feet of the main panel, the National Electrical Code (NEC) recommends using a conductor of at least 3 AWG copper or 1 AWG …3 AWG copper wire is the 60 amp sub panel wire size if the main’s 150 feet away and assuming the voltage drop reaches as high as 30%. That’s because if we factor in the 80% rule and the 30% voltage drop, such a setup will require a wire that can handle 97.5A in reality. If the main panel’s over 200 feet away, you can use a 4 AWG copper or ...an un-insulated ground wire that is wrapped around the conductors, and a final outer covering. Though its use is ... #1-3 w/gnd feeder for 100 amp SUB services SER Round Cable #4/0-3 w/gnd feeder for 200 amp SUB services ... #4/0 underground feeds for 200 amp services** * Size of motor and distance of run determine what size of wire is neededIf you've got a mono amplifier, you've got a great opportunity to really bring on the bass. Mono amplifiers are especially well-suited to wiring to two subwoofers. To wire two subw...Sub-panels hold two to 12 breakers. For a six-space panel used indoors, a 100-amp wire size is needed, while a two-space outdoor panel can work with a 60, 100, or 200-amp wire. Always check the product rating to make sure you’re using the correct wires. Indoor vs. Outdoor PanelsThis video demonstrates How to wire and properly ground a 30 Amp sub-panel. Perform at your own risk. If not comfortable, do not perform.The minimum width is 30 inches or the width of the panel, whichever is greater. The depth, i.e. the distance between the front of the panel and any obstructions, needs to be at least 36 inches. The minimum height is 6-1/2-feet. A good comparison for the clearance space, says Williamson, is the size of a standard refrigerator. If we have to run single phase 120V circuits or 2-poles 240V GFCI breaker, we will connect the white neutral wire from the main service panel to the subpanel box. Click image to enlarge. Keep in mind that #3/0 gauge wires should be used for 200A breaker and #1/0 gauge wire for 150A circuit breaker (NEC 2017 – Table 310.15 (B) (16) & 310.15 (B ... 100 Amp Sub Panel Wire Size Chart - Greenbushfarm.com. Electrical box or not? Converting 240 sub panel to 120 : r/electricians 100 amp sub panel wiring diagram. 13+ 30 amp sub panel wiring diagram [get 33+] 100 amp sub panel wiring diagramElectric work: 100 amp sub panel wiring diagram...main panel to send out.Even a 12-space panel will run out of spaces before it runs out of power. So I would advise something more like a 24-space, even a 30 would not be excessive. Breaker spaces are laughably cheap compared to the cost of having to change out a panel because the originally-chosen one was too small. There's no worry if the bus rating of the panel ...The same goes if you're trying to wire a 100 amp sub panel from a 200 amp main panel and feed it with a 100A breaker. That would require a 4-gauge copper or 2-gauge aluminum. Remember: you can use any sub feed panel size as long as its current rating is less than or equal to the size of the breaker feeding it.If you are installing a 60 amp sub-panel #6 wire is good for 65 amps at 75°C. (You have to use the 75°C rating since no one makes a 90°C rated breaker.) Using schedule 80 PVC you can fit 5 - #6 wires in a 1" pipe. You can fit 3 in a 3/4" but you need to pull a ground wire too so you will have to upsize to 1".Options include THHN, XHHW, UF-B, USE, and SER. Typical sizes of wires for 100 Amp Service are 4 AWG or 2 AWG for copper wiring and 2 AWG, 1 AWG, or 1/0 AWG for aluminum or copper-clad wiring. These sizes are also used for direct burial. When choosing 100 amp service wire size, remember that a 100 amp circuit at 240V can … 5000. 700. 1200. 6000. 800. 1200. Note: View wire size charts from the list below. Maximum Allowable Ampacities for Conductors in Raceway, Cable or Earth (30°C) Maximum Allowable Ampacities for Conductors in Free Air (30°C) Maximum Allowable Ampacities for Conductors in Raceway, Cable or Earth (40°C) Maximum Allowable Ampacities for ... As for your equipment ground conductor (EGC), you'll need a #8 copper wire or #6 aluminum wire for a 100 amp feeder. If you decide the savings is worth it, and you decide to go aluminum, you'll need #1 AWG XHHW wire for the hots and neutral.

3 AWG copper wire is the 60 amp sub panel wire size if the main’s 150 feet away and assuming the voltage drop reaches as high as 30%. That’s because if we factor in the 80% rule and the 30% voltage drop, such a setup will require a wire that can handle 97.5A in reality. If the main panel’s over 200 feet away, you can use a 4 AWG copper or .... 1998 ford expedition lug pattern

100 amp sub panel ground wire size

It's perfectly legal to feed a panel rated for "X" amps with a breaker smaller than "X" (and corresponding smaller wire). The rating is a maximum, not a level you're required to achieve. You may not have load-calculation capacity for an extra 100A, 90A wire can be significantly less expensive than 100A wire, etc. – nobody.I am installing a 100 Amp sub panel in my detached garage for a 40 Amp car charger It is 70' away, 30' in the basement and then 40' outdoors. I am going to be running it using XHHW 1/0,1/0,1/0,2awg Aluminum wire in 1.5" PVC conduit.The wire run is 30' through he house rafters, then 22' outside the house in conduit, 10' drop into the ground, 50' underground in conduit, and then 8' up from the ground in conduit and into the new garage panel box. - Joe. ... What wire size for 100 Amp sub panel 100ft in length from 200 Amp main panel? 1.The minimum conductor size allowed is #1 aluminum, which is 83.7 kcmil in cross-section. The minimum ground wire size allowed is #6 aluminum, which is 26.3 kcmil in cross-section. When you enlarge the conductors for any reason, you must also enlarge the ground in proportion. So the ground is 26.3/83.7 = 31.4% of the conductors.To feed a 100amp sub panel that is 200 feet away, you will need at least a 1 AWG copper wire or simply #3 copper wire. Alternatively, you can use 2/0 aluminum wires. These two wire sizes are enough to carry 100 amp throughout that distance.When installing a 100-amp sub panel, the size of the ground wire is a crucial factor to consider. The National Electrical Code (NEC) specifies that a ground wire of at least 8-gauge should be used for a 100-amp sub panel. This provides a safe path for electricity to flow in the event of a fault, preventing equipment damage or electrical shock.The subpanel will be 60 amp. The garage is about 30' from the main-panel in-house, and I will of course get an exact length before selecting the ... Grounded (neutral) and grounding bus must be separate at sub-panel (250.32(B)(1)). No need for a GFCI breaker in the main panel, unless your local code requires it. ... a potential to have a live ...60 ampere double pole breaker in the main panel. 6 AWG copper wire (x4) for a run less than 75ft., 4 AWG copper wire (x4) for runs less than 150ft. 60 ampere panel with 60 ampere main breaker. Unless you're running a whole bunch of stuff at once, a 60 amp panel should serve you well.Correction:. I meant to say #8 for the ground. Thanks all, I will go with #3 for neutral and #8 for my ground. In most cases the grounding electrode conductors (ground wires to ground rods etc.) are #6 copper to direct buried or driven rods and #4 copper to water pipe or concrete encased rods.Generally, the ground wire size for a 200 amp service ranges from 2 AWG to 8 AWG. The best one is 2 AWG for copper wire and 4 AWG for aluminum or copper-clad aluminum wire. It is recommended to use them with 1.5-2.5 inches schedule 40 or 80 PVC conduit for underground service. It may differ depending on the materials, permission rules, codes, etc.Inside the main panel will be a breaker which feeds the wiring to the subpanel. The lesser of those current ratings decides the size this breaker must be. Example: you have a 200A subpanel connected via 6 AWG feeder. This must be fed by a 60A breaker in the main panel. The wire size is the limiting factor..